Case studies

What we have done, with real data

Wineries and cava cellars, olive oil cooperatives, a large brewery, a foundry, an electronics manufacturer and laser cutting workshops. We do not publish our clients' names, but we do publish the application, the region, the flows, the pressures and what we did.


What our clients say
Estic agraït a la labor d’enginyeria feta pel Rafel. Ara sí que tota la feina del molí va amb oli.

I am grateful for the engineering work done by Rafel. Now the whole mill really runs as smooth as oil — never better said.

X.V.Olive oil cooperative · Segrià (Lleida)
Des que hem muntat la planta generadora de N₂, en Rafel ha posat sempre els seus coneixements tècnics al nostre servei, entenent perfectament les prioritats, les necessitats i l’eficiència, sempre sense perdre de vista l’economia.

Since we installed the N₂ generation plant, Rafel has always put his technical knowledge at our service, understanding our priorities, needs and efficiency perfectly, without ever losing sight of the economics.

C.P.Laser cutting · Manresa area
Wine bottler · Tarragona

From 200-bar cylinders to its own nitrogen

Compact PSA nitrogen generator with its tanks next to the filling line of a wine bottler
The plant, next to the filling line.
Modular PSA nitrogen generator and buffer tank mounted on a single skid
Generator and tank on a skid.
Stainless steel sterile filter at the nitrogen point of use, next to the filler
Sterile filter at the point of use.
The challenge
A wine bottler inerted its filling line with nitrogen from 200-bar cylinders: cylinder changes, rentals, transport and dependence on the supplier.
What we did
Compact skid-mounted plant: modular PSA generator and N₂ buffer tank, installed next to the filler. At the point of use, a stainless steel sterile filter before the machine. Annual maintenance with the N₂ quality certificate included.
Result
The line produces its own nitrogen, with no cylinders and quality certified every year.
The savings
Compared with the cost of 200-bar cylinders, the investment pays back in about 8 months.
  • Payback ≈ 8 months
  • Compact skid-mounted plant
  • Sterile filter at the point of use
  • Annual quality certificate included
Ductile iron foundry · Biscay

99.999 % nitrogen for casting and the laboratory

The challenge
A ductile iron foundry bought cryogenic nitrogen for two critical uses: inerting the casting ladle, so that the molten iron does not oxidise or form inclusions, and supplying its analytical equipment. It paid about €40,000 a year and depended on the gas supplier's prices and lead times.
What we did
Very high purity modular PSA generator, with residual O₂ always below 10 ppm (99.999 %). An activated carbon tower at the inlet protects the carbon molecular sieve from oil vapour. The generator was integrated into the plant SCADA through a protocol gateway, validated variable by variable with the plant team.
Result
The foundry produces its own nitrogen, monitored from the same SCADA as the rest of the plant and with no tanker trucks.
The savings
Before, ≈ €40,000 a year on cryogenic nitrogen; now, ≈ €11,000 for energy and maintenance. Expected savings were ≈ €29,000 a year and, with consumption optimisation, reached ≈ €32,000. The investment pays back in under 18 months, and without gas transport about 25 t of CO₂ a year are avoided.
  • ≈ €32,000/year saved
  • Payback < 18 months
  • 99.999 % · O₂ < 10 ppm
  • ≈ 25 t of CO₂ avoided per year
Electronics manufacturer · feasibility study

700 Nm³/h at 99.999 % with a hydrogen purifier

The challenge
Replacing about 4.3 million Nm³ a year of liquid nitrogen, with peaks of 900 to 1,000 Nm³/h, for reflow ovens and wave and selective soldering.
What we proposed
Three PSA generators at 99.5 % (two plus one standby), a hydrogen electrolyser and a palladium catalytic purifier for 700 Nm³/h, with 40-bar storage to cover peaks.
The savings
≈ 0.30 kWh per Nm³ at 99.999 % and an electricity cost of ≈ €0.03/Nm³, versus ≈ €0.08/Nm³ for liquid nitrogen. Estimated payback of about 3.7 years.
  • 700 Nm³/h · 99.999 %
  • O₂ < 10 ppm · −60 °C
  • ≈ 40 % less energy than a direct PSA
  • See the solution →
Sparkling-wine cellar · Penedès

Half the nitrogen, in the middle of harvest

The challenge
The PSA generator was delivering half its flow, the cycle pressures were abnormal and the purity reading made no sense. The cellar needed the N₂ for tank inerting, tirage and sterile filtration.
What we did
On-site diagnosis the day after the call. The refrigerated dryer had stopped, water got into the air line and clogged the activated-carbon tower. With that pressure drop, the towers did not get above ≈ 4 bar. We replaced the carbon charge and the pressure regulator, and adjusted the O₂ sensor until it could be replaced.
Result
The towers are back at ≈ 7 bar and production recovers. To stop it happening again, and for the new filler, we propose a dedicated dryer and a second generator in parallel.
  • ≈ 4 → ≈ 7 bar in the towers
  • 4 purity checks a year (IFS/BRC)
  • 9,000 bottles/h filler ≈ 27 Nm³/h
Large winery · Penedès

From 15 to 60 Nm³/h without stopping the winery

3D design of the expansion: two PSA generators in parallel with air and nitrogen tanks
Expansion design: second generator in parallel, shared storage and a single network.
The challenge
The N₂ plant was commissioned in 2023 with 15 Nm³/h. As the winery grew, it fell short.
What we did
Expansion with a second PSA generator, shared storage and a single distribution network, without interrupting supply. Commissioning and certification of N₂ quality at the points of use.
Result
The winery quadruples its nitrogen capacity and gains redundancy: if one generator stops, the other keeps producing.
  • 15 → 60 Nm³/h
  • 2 generators, 1 network
  • Purity certification
Cava cellars · Penedès

Purity you can prove in any audit

The challenge
Food-safety audits (IFS, BRC, ISO 22000) require proof that the N₂ in contact with the wine meets specification.
What we did
We certify the quality of the plant's nitrogen with a calibrated oxygen analyser holding a current calibration certificate.
Result
Independent certificate, digitally signed and ready to hand to the auditor. See the service →
  • Calibrated analyser
  • Digitally signed certificate
  • Annual or quarterly
Large Catalan brewery

A generator at 99.9 %, checked every year

The challenge
PSA N₂ generator in continuous service at a large brewery: 99.9 % purity, ≈ 42 Nm³/h at 7 bar.
What we did
Annual N₂ quality certification, fault diagnosis and review of inlet air treatment.
Result
Purity is documented year after year and faults are solved with a technical diagnosis, not by blindly changing parts.
  • 99.9 % N₂
  • ≈ 42 Nm³/h · 7 bar
  • Annual certification
Laser cutting · Manresa area

High pressure for cutting thick plate

Nitrogen plant with compressor, dryer, PSA generator, tanks and high-pressure cylinder bundles
The plant: PSA generator, booster and high-pressure cylinder bundles.
The challenge
A laser cutting workshop bought N₂ in high-pressure cylinders, about 40 a week, to cut thick plate. It cost ≈ €2.19/Nm³.
What we did
Plant with PSA generator, booster and cylinder bundles. The laser cuts with compressed air up to 3 mm and with N₂ above that. Plus our own documentation: operating manual, costed preventive maintenance plan, critical spares and booster guide, with a training session for the engineering team.
Result
Plant in full operation and a team that knows how to run and maintain it.
The savings
Investment of ≈ €85,000: ≈ €75,000 in equipment and ≈ €10,500 for installation and legal registration. It used to pay ≈ €57,500 a year for cylinders; now ≈ €8,100 for energy and maintenance (≈ €0.31/Nm³). Savings of ≈ €49,000 a year: according to our feasibility study, the plant pays for itself in about 21 months.
  • ≈ €49,000/year saved
  • Payback ≈ 21 months
  • 11 Nm³/h at 99.999 % · 200 bar
  • 4 in-house technical documents
Stainless laser cutting and welding · Alt Penedès

An N₂ plant for cutting and welding

The challenge
A stainless steel manufacturer wanted to produce its own nitrogen for laser cutting and welding.
What we did
Technical approach, flow and pressure sizing, selection of the generator manufacturer and goods-receipt inspection report.
Result
Project won against competitors; plant being installed in 2026.
  • Cutting + welding
  • In-house sizing
  • Receipt inspection
Olive oil cooperative · Les Garrigues (Lleida)

The tank was reading 2,000 L too much

PSA nitrogen plant at an olive oil cooperative: compressor, dryer, air and N₂ tanks and twin-tower generator
The N₂ plant: compressor, dryer, tanks and twin-tower PSA generator.
Olive oil bottling line
The olive oil bottling line.
The challenge
Olive oil tanks inerted with N₂ (blanketing). With the tank pressurised, the level indicator read between 1,000 and 2,000 L more than after venting.
What we did
Supply of the PSA generator, with zirconia O₂ sensor, purity safety valve and flowmeter. During the visit we measured ≈ 31 mbar of N₂ in the headspace: each mbar raises the indicator column by ≈ 1.1 cm.
Result
Technical report explaining why, with a simple reading procedure for the miller: the right reading is the one after purging.
  • ≈ 31 mbar blanketing
  • 1,000–2,000 L error explained
  • Generator with purity control
Olive oil cooperative · Segrià (Lleida)

Nitrogen in the transfer line

The challenge
The cooperative did not use nitrogen in oil production and wanted to protect it from oxidation, including while pumping it from one tank to another.
What we did
Complete plant with its own compressor, dryer, 40 Nm³/h PSA generator at 99.5 % and sterile filtration for food grade. Injection into the 1½" stainless pipe: pressure regulator, needle flowmeter and non-return valve, no automation. The N₂ travels with the oil and ends up in the tank headspace.
Result
Inerted during transfer, simply and without depending on a PLC.
The savings
Investment of ≈ €58,000: ≈ €53,400 in equipment, compressor included, and ≈ €4,600 for installation. Producing 1 Nm³ of N₂ costs ≈ €0.03 in electricity, plus ≈ €4,000 a year for maintenance. Had the cooperative bought that nitrogen, by our estimate the plant would pay for itself in about 6 months versus cylinders and about 14 months versus liquid N₂, saving more than €40,000 a year.
  • Investment ≈ €58,000
  • Payback 6–14 months (estimated)
  • > €40,000/year saved
  • ≈ €0.03/Nm³ electricity
And the savings?

From €0.22 to €0.11 per Nm³: half the cost

Example of a plant consuming 150,000 Nm³ of N₂ a year. With cryogenic supply, adding gas, tank rental, delivery and boil-off losses, nitrogen costs it €0.22/Nm³. With on-site PSA generation, counting energy, maintenance and equipment depreciation, €0.11/Nm³.

€0.22per Nm³ with cryogenic
€0.11per Nm³ with on-site PSA
≈ €16,400saved per year
≈ 32 monthsto recover an investment of €60,000

Full calculation, with all the assumptions, in our article How to calculate the real cost per Nm³. Typical payback for a PSA plant is between 18 and 36 months, depending on consumption, purity and electricity price.

For confidentiality we do not show names or data that could identify our clients. If your case resembles one of these, tell us and we will run the numbers together.

Request a no-obligation technical consultation

We read your enquiry personally and reply within 48 working hours at most.

Request a technical consultation →
WhatsApp