Low-cost nitrogen
The generator works where it is most efficient: about 2.9 Nm³ of air per Nm³ of N₂ and a compressor less than half the size.
A PSA generator can reach 99.999 %, but at a price: it needs about 6.6 Nm³ of compressed air per Nm³ of nitrogen, versus about 2.9 Nm³ at 99.5 %. For the same flow, compressor and generator are more than twice the size, and so is the electricity bill.
With small flows the difference can be absorbed. With hundreds of Nm³/h around the clock, it is the item that decides whether the project is viable.
The generator works where it is most efficient: about 2.9 Nm³ of air per Nm³ of N₂ and a compressor less than half the size.
An electrolyser produces hydrogen on site: two molecules of H₂ for every molecule of O₂ left in the nitrogen. For 700 Nm³/h at 99.5 %, about 7 Nm³/h of H₂.
On the catalyst, residual oxygen and hydrogen react: 2 H₂ + O₂ → 2 H₂O. No combustion temperature or flame is needed.
An adsorption dryer removes the water formed. Nitrogen leaves at 99.999 %, with O₂ below 10 ppm and a dew point below −60 °C.
Hydrogen is neither bought nor stored: it is produced on demand by electrolysis of water. The current splits the water molecule: hydrogen leaves at the cathode and oxygen at the anode, and a diaphragm keeps them apart.
The electrolyser uses about 0.9 litres of demineralised water per Nm³ of hydrogen: for the 700 Nm³/h example, around 6 to 9 litres per hour. The by-product oxygen is vented outdoors.
It is not the answer for small flows or food-grade nitrogen: there a PSA at the right purity is simpler.
Dosing is stoichiometric: two parts hydrogen for each part oxygen, adjusted to the measured oxygen. A minimal trace of hydrogen may remain. In electronics soldering and heat treatment this is not a problem, and often an advantage. If your process has a hydrogen limit, we take it into account in the design.
Argon from the air (around 0.9 %) accompanies nitrogen in the PSA. It is an inert gas and does not affect these processes. The 99.999 % specification refers to residual oxygen, which is what matters.
The purifier makes sense from about 50 Nm³/h, and the savings grow with flow and operating hours. The comparison on this page shows the order of magnitude for your case; we give the exact figure with the study.
That of a PSA generator, plus the electrolyser (water, electrolyte and cell), the purifier's catalyst and adsorption dryer, and analyser calibration. We plan it all in a single annual plan.
Because they depend on flow, purity, storage pressure and what you already have installed. After the study we give you a fixed quotation and the cost of your Nm³.
Tell us your flow, purity and pressure, and we will compare both solutions with your figures.