An oxygen generator works the other way round from a nitrogen one. Its columns are not filled with carbon sieve but with zeolite: a crystalline aluminosilicate with molecule-sized cavities and metal cations (sodium or lithium) inside.
Those cations create a strong electric field on the cavity surface. The N₂ molecule has a quadrupole moment about four times larger than O₂, and that field holds it much more strongly. At equilibrium, zeolite loads several times more nitrogen than oxygen. It is an equilibrium separation, not a kinetic one.
Lithium zeolites (LiX type) are more selective than conventional 13X and need less air per Nm³ of oxygen. We choose the adsorbent and the cycle according to the flow and purity you need.
While one column retains nitrogen under pressure and delivers oxygen, the other is depressurised and releases it to atmosphere. The product buffer keeps flow and pressure constant during changeovers.
Air enters at 7 bar(g). Zeolite retains nitrogen, moisture and CO₂; oxygen and argon pass through and leave towards the buffer.
Before the nitrogen front reaches the outlet, both columns are connected. The pressurised one passes oxygen-rich gas to the one about to start.
The saturated column is opened to atmosphere. As pressure falls, the zeolite releases the nitrogen it had retained.
A fraction of the product oxygen sweeps the column counter-current and carries the residual nitrogen away. The column is ready to produce.
To obtain one Nm³ of oxygen, almost four of nitrogen have to be retained, and part of the oxygen is lost in venting and purge. That is why an O₂ generator needs between 10 and 12 Nm³ of compressed air per Nm³ of product, several times more than a nitrogen generator.
An example: 20 Nm³/h of O₂ at 93 % needs about 220 Nm³/h of air, close to 3.7 m³/min. Compressor efficiency drives much of the cost of your oxygen.
For most industrial uses — aquaculture, wastewater, ozone, combustion — 90–93 % is enough.
Nm³ of compressed air at 7 bar(g) per Nm³ of O₂ produced. The balance of the product up to 100 % is argon and nitrogen.
Each model is named after its flow at 93 %. Choose the purity to see the flow of every model and the compressed air it uses, or try the “Which model do I need?” tab.
| Model | Flow | Compressed air Nm³/h | Connections air / O₂ |
|---|
Flows in Nm³/h with inlet air at 7 bar(g), 20 °C, dry and oil-free. With other inlet conditions the flow changes: we calculate it for your installation. “Compressed air” is the generator consumption at full output. For larger flows we design units in parallel.
Zeolite is strongly hydrophilic: water adsorbs on it even more strongly than nitrogen. If the air arrives wet, vapour takes the active sites, the zeolite loses capacity and purity falls. That is why the air must arrive dry, filtered and oil-free, and many columns carry a layer of activated alumina at the bottom to hold residual moisture.
As with nitrogen, the air receiver, pressure stability and inlet temperature are part of the generator's performance.
The largest consumer in the plant: air/O₂ factor of 10 to 12.
Dry air to protect the zeolite.
Particulate, coalescing and activated carbon.
Stable inlet pressure.
Two zeolite columns and cycle control.
Constant flow and pressure to the process.
Continuous O₂ purity with alarm.
Oxygenation of tanks and pens: more biomass per m³ and less stressed fish in summer.
Oxygenation of biological basins to absorb load peaks and reduce odours without enlarging the plant.
Feeding the ozone generator with oxygen instead of air multiplies the ozone produced per kWh.
Enriching combustion raises flame temperature, reduces flue-gas volume and saves fuel.
Oxy-fuel torches for glass blowing, lampworking and goldsmithing, with no cylinder changes.
For operations that do not require high-purity cylinder oxygen.
Because zeolite retains nitrogen but does not tell argon from oxygen. Air contains 20.9 % O₂ and 0.9 % argon, and both leave together as product. Even if all the nitrogen were removed, the theoretical limit would be 95.7 % O₂.
Higher purities (99.5 % and above) require liquid oxygen or a second argon-separation stage.
Between 10 and 12 Nm³ of air at 7 bar(g) per Nm³ of O₂, depending on purity. That is far more than a nitrogen generator, because oxygen is only a fifth of the air and almost all the rest has to be retained.
That is why the compressor and its efficiency set the cost per Nm³ of oxygen, and we size it together with the generator.
Oxygen for human use is a medicinal product, and its on-site production is subject to specific health regulations. The equipment in this range is offered for industrial use. If your project is medical, ask us and we will point you in the right direction.
Air-line maintenance (filters, dryer and drains), inspection of the cycle valves and calibration of the oxygen analyser. With dry, oil-free air, zeolite keeps its capacity for many years.
What harms it most is moisture: if the dryer fails, water takes the active sites of the zeolite and purity falls.
For continuous consumption at 90–95 % purity, a PSA generator usually offers a much lower cost per Nm³ and removes tank rental, deliveries and boil-off losses. Liquid oxygen makes sense for high purities or very occasional consumption.
Many plants combine both: the generator covers the base load and liquid oxygen stays as back-up.
Because the real cost depends on the complete plant: compressor, drying, filtration, receivers and installation. After the study we give you a firm quotation and the cost of your Nm³ of oxygen.
Tell us your consumption, the purity you need and how you buy oxygen today. We come back with the model, the compressor and the cost per Nm³.